12 Years manufacturer SV-8000 PU Sealant for Insulating Glass Supply to Sri Lanka

12 Years manufacturer SV-8000 PU Sealant for Insulating Glass Supply to Sri Lanka
  • 12 Years manufacturer SV-8000 PU Sealant for Insulating Glass Supply to Sri Lanka12 Years manufacturer SV-8000 PU Sealant for Insulating Glass Supply to Sri Lanka

Short Description:

Description SV – 8000 two-component polyurethane insulating glass sealant is a neutral cure, mainly used for the insulating glass of the second seal. Product formulation to use its performance with high modulus, high strength, to meet the requirements of insulating glass assembly.   Where to use It is a two-component PU sealant that offers variable work life with high bonding strength to maintain the integrity of insulating glass unit, suits both commercial and residential IGU.   Key Fe...


Product Detail

Attentions

Application

Product Tags

It is a good way to improve our products and service. Our mission is to develop creative products to customers with a good experience for 12 Years manufacturer SV-8000 PU Sealant for Insulating Glass Supply to Sri Lanka, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!


Description

SV – 8000 two-component polyurethane insulating glass sealant is a neutral cure, mainly used for the insulating glass of the second seal. Product formulation to use its performance with high modulus, high strength, to meet the requirements of insulating glass assembly.

 

Where to use

It is a two-component PU sealant that offers variable work life with high bonding strength to maintain the integrity of insulating glass unit, suits both commercial and residential IGU.

 

Key Features

1. High Modulus

2. UV resistance

3. Low vapor and gas transmission

4. Primerless adhesion to coated glass

 

Technical data sheet

Test project standards Value
Sagging degree (mm) ≤3 0
Operating time ≥30 30
Thermal weight loss(%) ≤10 2
Durometer Hardness Shore A 20-80 42
tensile propcrties(MPA) >0.4 1.0
Bond damage area(5%) ≤5 0

 

Certification

GB-24266-2009;

 

Color

Component A(Base) – White, Component B(Catalyst)- Black

 

Package

1. Component A(Base): (190L), Component B(Catalyst) (18.5L)

2. Component A(Base):24.5kg (18L), Component B(Catalyst): 1.9kg (1.8L)

 

Shelf life

12 months

 

Note

If you want the TDS or MSDS or other details, please contact with our sales person.

 

  • Previous:
  • Next:



  • Laboratory demonstration of a 6 Axis robot applying RTV material on automobile engine components.

    The application uses Nordson Prometer S Shotmeter with Autoflo valve.



    https://www.drenergysaver.com | 1-888-225-6260

    Fifty years ago, before central air conditioners became the norm for cooling US homes, whole house fans were used for that purpose. Installed on the uppermost levels of the house, they were actually big exhausters, which would suck hot air from inside the house and into the vented attic, causing air from the outside to be sucked in through open windows and doors.

    The reason why whole house fans became obsolete is that they don’t allow homeowners to really control the temperature or comfort inside the house — like they can do with air conditioners. If the outside air is too hot and muggy, that is the kind of air that will be brought into the home.

    Nevertheless, many homes in the U.S. still have whole house fans installed — and whole house fans represent a big gap in the building envelope, and can become a huge source of energy waste during the winter.

    Because of a physics phenomenon known as the “stack effect,” a lot of warm air — the air that you pay to heat in the winter — is escaping through that fan, into the vented attic, even when the fan is turned off.

    When homeowners no longer use the whole house fan, Dr. Energy Saver usually recommends removing it entirely and patching the hole left in the ceiling with drywall.
    Some homeowners, however, still like to use whole house fans to cool the house when the weather outside is nice and comfortable. So what can be done in these cases?

    In episode 68 of the On the Job video series, Larry Janesky, shows us how Dr. Energy Saver deals with cases like this. The challenge is to allow the homeowner to use the whole house fan when he so chooses, but also keeping it from becoming a source of energy waste when the heating or air conditioning system is being used.

    This particular attic received a lot of upgrades in order to become energy efficient, including an insulated storage deck, can light covers, Rockwool insulation and sealing around the chimney, duct sealing, a cat walk and insulation dams to contain several inches of blown cellulose, as well as professional air sealing.

    The whole house fan in this case received a cover made of SilverGlo foam insulation board and completely air sealed. An airtight lid — which can be removed by the homeowner when he turns the fan on — keeps the unit fully functional, while preventing energy waste when the fan is not being used.

    Whole house fans are only one of the many energy wasting details Dr. Energy Saver technicians find and fix every day, in homes across the U.S. — and we would love to help you too!

    Visit our website or call us to locate a Dr. Energy Saver dealer in your area that can make your home more comfortable and energy efficient.

    Related Products

    WhatsApp Online Chat !